Anesthesia Workstation Practice 3700

Anesthesia Workstation for newborns, children and adults with integrated monitor to display the respiratory parameters of the patient. It is a continuous pneumatic, electronically controlled anesthesia ventilator.

PCV and SIMV+PS modes ensure flexibility in ventilation strategy

Optional monitoring functions, CO2 and anesthetic gas

Flow meter provides a minimum of 25% concentration of oxygen in O2/CO2 mixture

Optional CO2 bypass and heating system

Supports two vaporizers (filling type: pour-fill, key-fill, and quick-fill)

Features:

  • Anesthesia Workstation for newborns, children and adults with integrated monitor to display the respiratory parameters of the patient. It is a continuous pneumatic, electronically controlled anesthesia ventilator.
  • PCV and SIMV+PS modes ensure flexibility in ventilation strategy
  • Optional monitoring functions, CO2 and anesthetic gas
  • Flowmeter provides a minimum of 25% concentration of oxygen in O2/CO2 mixture
  • Optional CO2 bypass and heating system
  • Supports two vaporizers (filling type: pour-fill, key-fill, and quick-fill)

Specifications:

PRACTICE 3700

 

Pneumatic specification
Gas supply O2, N2O, Air: 0.28 – 0.6 Mpa
Working mode closed, semi-closed, semi-open
Driven mode Pneumatically driven and electronically controlled
Safety valve
Operating mode
Flowmeters O2: 0-1, 1-10 l / min

N2O: 0-1, 1-10 l / min

Air: 0-1, 1-12 l / min

O2 flush: 25 – 75l/min

Ventilator Specification
Patient Type Adult, pediatric
Ventilation modes IPPV, PCV, SIMV+PS, PS, Manual
Setting Touch-key & navigator wheel knob
Tidal volume 20 – 1500 ml
Respiratory rate 4 – 100 bpm
I:E ratio

 

4:1 – 1:8
Ppeep

 

3 – 30 cm H2O
Pmax
Inspiratory plateau Off, 5% – 60%
Pressure range 5 – 70 cm H2O
Trigger sensitivity (flow) 1 – 15 l / min
Alarm Pressure: Paw high/low limit

Sustained airway pressure

Volumes: MV high/low limit

Gas: FiO2 high/low limit

Respiratory rate is too high

Low O2 supply pressure

Apnea

Power failure

Monitoring display 10.4 inch TFT color screen

Pressure Paw, Ppeak, Pplat, Pmean, PEEP

Volume: MV, Vt, Freq

Respiratory rate

Gas: FiO2, optional: CO2, AG, MAC

Graph: P-T, F-T

Curves: P-V, F-V

Optional – CO2-t

 

 

Electrical specification
Mains 100 – 240V AC, 50/60 Hz

 

Battery 24V DC (min. 120 min)

 

Physical & Enviromental Specification
Storage  temperature -20  –   +60°C
Storage humidity ≤95%
Working  temperature +10  –    +40°C
Dimensions (H×W×D) 1300×800×630 mm
Weight 100 kg  (basic unit)
Vaporizer Support 2 vaporizer
Agent type Halothane, Enflurane, Isoflurane, Sevoflurane available

Basic service

oui décor